0–300 mbar · Ø 22 mm probe · 5 m cable · IP68
Request a demo
Hydrostatic Monitoring for Demanding Tank Environments
FoxPressure (Gen 4) is a hydrostatic pressure-based level sensor for deep, narrow, or geometrically constrained tank installations. It is used where radar-based sensing cannot deliver stable, reliable readings — enabling accurate level data in tanks that would otherwise be difficult or impossible to monitor.
It integrates into FoxPortal to support consumption-based forecasting, refill planning, and portfolio-wide visibility.
Core Capabilities
Measurement & Hardware
- Accurate level data from tanks that would otherwise be invisible — deep, narrow, or geometrically constrained
- Hydrostatic pressure measurement works regardless of tank shape, internal obstructions, or line-of-sight
- Stainless steel probe rated for long-term submersion in industrial liquids — IP68 throughout
- Weatherproof housing for demanding outdoor and underground installations
- On-device display for instant on-site level checks without opening the app
Connectivity & Power
- Multi-network connectivity adapts to any site infrastructure — NB-IoT, LTE-M, 2G, Wi-Fi, or Bluetooth
- Integrated eSIM eliminates SIM card logistics across large fleets
- Long battery life even in hard-to-access or underground locations
- 5 m probe cable reaches the base of most heating oil and diesel tanks
Where FoxPressure Gen 4 Fits
FoxPressure Gen 4 is the right choice when tank geometry or installation conditions prevent reliable radar measurement.
- T-piece installations — radar produces erratic or incorrect readings in this configuration
- Deep or narrow tanks where radar line-of-sight is not achievable
- Tanks with internal cross-bracing, edges, or obstructions
- Underground fuel storage with constrained or angled access
- Heating oil tanks with complex internal geometry
- Industrial fluid storage where mounting constraints prevent radar use
Industry applications: Heating Oil · Diesel · Lubricants
Ideal Use Cases
- Heating oil and diesel tanks with complex geometry, T-piece connections, or deep profiles
- Underground tanks and sites with constrained or angled access openings
- Installations where radar cannot deliver stable, reliable readings
- Distributor portfolios requiring complete tank coverage across all tank types
Deployment Requirements
- Requires a suitable threaded opening or compatible adapter for probe insertion
- Standard probe covers approximately 3.5 m depth for heating oil and diesel (0–300 mbar)
When to Use a Different Sensor
FoxPressure Gen 4 is not the default sensing option. Consider an alternative when:
- Radar measurement is stable and feasible for the tank type (→ use FoxRadar Gen 4)
- No suitable threaded opening exists for probe insertion
- Installation constraints favour fully contactless measurement
- The environment requires ATEX/IECEx certified hardware (→ use Pressure EX)
Role Within the FoxInsights System
- Accurate level data from complex and constrained tank installations
- Data transmission to FoxPortal for consumption analysis
- Full inclusion of difficult tanks in consumption-based forecasting
- Reliable planning input across all tank types — not just standard ones
Execution remains with your operations team.
Integrated with FoxPortal
- Portfolio-wide visibility including complex and constrained tanks
- Consumption-based forecasting with complete tank coverage
- Structured refill planning without monitoring gaps
Technical Specifications
Measurement
| Property | Value |
|---|---|
| Measurement method | Hydrostatic pressure measurement |
| Pressure range | 0–300 mbar (approx. 3.5 m oil column) |
| Accuracy | ±5 mm fill level | ±0.25% FS (typical) |
| Sensors | Pressure sensor, GPS, tilt sensor, temperature |
Probe
| Property | Value |
|---|---|
| Probe diameter | Ø 22 mm |
| Cable length | 5 m |
| Probe materials | Stainless steel 316L, PUR measurement hose, NBR gasket |
Display
| Property | Value |
|---|---|
| Display | 1.52" eInk for level, signal & diagnostics |
Connectivity
| Property | Value |
|---|---|
| Radio technology | LTE NB-IoT, LTE Cat-M, 2G, Wi-Fi (802.11 b/g/n/ax), Bluetooth LE |
| SIM | Integrated eSIM |
| Transmission interval | Configurable, default: 1× per day |
| Data protocol | CoAP / MQTT |
Electrical Data
| Property | Value |
|---|---|
| Power supply | 3× Varta Industrial Pro C (LR14), 1.5 V (replaceable) |
| Battery life | >10 years at 1 measurement/day (Cat-M: 7–12 y, NB-IoT: 5–10 y, 2G: 2–5 y) |
Environmental Conditions
| Property | Value |
|---|---|
| Operating temperature | −20°C to +50°C |
| Protection class | IP68 (1 m / 60 min) |
Mechanical Data
| Property | Value |
|---|---|
| Connection | Universal thread adapter (2", 1½", 1¼", 1"), adhesive adapter |